Waste and vent pipe installation

Learn about the installation of waste and vent pipe fittings, and view pipe fitting styles.

homeowner-plumbing-permit-banner

Installing waste and vent pipes and fittings

Approved materials

Waste and vent pipes and fittings:

Cast iron, galvanized steel, galvanized wrought iron, copper, brass, Schedule 40 ABS DWV, and Schedule 40 PVC DWV are some commonly used approved materials. 

Before you buy materials

Drainage Fixture Unit Value Table (DFU):

Look at the DFU to see the size of pipe you will need for the project. Each type of fixture has a different value and minimum size for the waste and vent pipes.

Cleanouts (applies to first floor only):

A "cleanout" is an access to a pipe that will make it possible to clean out the pipe if it becomes blocked. Be sure to use a cleanout made of an appropriate material. You will also need a cleanout for each horizontal change of direction exceeding 135º.

Lay the pipe

Drainage and grading:

Sewage runs downhill. All your waste pipe must be graded at 1/4 inch per foot; otherwise, you may have trouble getting the sewage out of your house.

Decide which fittings to use:

It is very important you use the correct plumbing fittings when installing your new system. Using the wrong fittings could cause sewage backups or other problems. See different types of fittings below.

  • Elbows: Use a 90º vent elbow (short turn) for venting only above the flood level. Use a 90º medium elbow for wastes going from horizontal to vertical and for vents above the flood level. Use a long turn 90º elbow for directional changes of vertical to horizontal and horizontal to horizontal.
  • Tees: Use a sanitary tee in vertical position only for trap application and horizontal to vertical drop.
  • Wyes: Can be used on vertical and horizontal and in many applications except fixture connections. Can also be used as a cleanout.
  • Combination Tee-Wyes: Can be used in all applications except to a trap arm.
  • Traps: A "p-trap" with a union must remain accessible but a p-trap with a solvent weld may be concealed.

Traps

A trap is a fitting or device so designed and constructed as to provide, when properly vented, a liquid seal which will prevent the back passage of air without affecting the flow of sewage or wastewater through it. Each fixture must be trapped to prevent sewer gas from coming up into your house. The weir of the trap must be below the opening to the vent. The trap seal shall be no less than 2 inches or more than 4 inches and installed true to the water seal.

Venting

The sizing of the vents shall be done using the fixture units table referenced above. Vents must be graded or be level so there are no drops or sags. For vent termination, each vent pipe must extend through its flashing and end at least 6 inches above the roof. Vents may be connected together at least 6 inches above the highest fixture flood level.

Pipe fitting styles

Horizontal to vertical connection

Vertical to horizontal connection

90-degree medium elbow

For wastes, horizontal to vertical change of directions, and for venting above flood level.

90-degree vent elbow

For venting above flood level only.

45-degree elbow

Long turn 90-degree elbow

Used for any directional changes.

Sanitary tee

For drainage, may be used in vertical position only. Most commonly used in trap arm application and horizontal to vertical drop.

Combination long turn tee wye

Used in vertical and horizontal position. Not for trap arms.

P-trap

Shown with solvent weld all glue joints.

Wye

Can be used in many applications except fixture connections (can be used as a clean out).